Add to Cart
ATD020 Portable Peltier Thermoelectric Dehumidifier / Peltier Condenser
Please contact Adcol for detailed specifications.
Mechanical Clamping Method
The following is a list of guidelines for using mechanical clamping:
1. The mounting surfaces (between which modules are to be clamped) should be flat to within 0.001”. 2. Mounting and module surfaces should be carefully cleaned to remove any grit, burrs, etc. 3. If more than one module is to be used in the assembly, all modules should be within 0.001” in height. 4. Use graphite pads as the thermal interfaces on both hot and cold sides. While not as conductive as thermal grease initially, over time it is the better alternative. 5. Bolt the object to be cooled and heat sink together using stainless steel fasteners with washers or split type lockwashers. Tighten each side a little bit at a time, alternating between screws, to insure an even pressure across the module surface. Maximum recommended compression loading is 350 lbs. per sq. inch of module surface.